Leave Your Message
Medical Accessories
Solutions
Solution Categories
Featured Solution

Medical Accessories

2025-07-03

Product Application - Medical Supplies

Medical Accessories (1)

Scalpel

Medical Accessories (2)

Spreader

Medical Accessories (4)

Medical bone biting scissors

Medical Accessories (3)

Bone knife bone chisel

Product Application - Reasons for Medical Product Failure

Corrosion

DLC  (1)

Wear and tear

Medical Accessories (6)

Every step in the use and handling of surgical instruments, including usage, pretreatment, soaking, cleaning, disinfection and sterilization, etc., can easily lead to surface wear, peeling and rusting of the instruments, causing damage to the instruments.

Main pain points

Dry storage of the instrument after use makes cleaning difficult and causes damage when scrubbing.

If the blood and other contaminants on the instruments are not initially wiped off, it will cause corrosion to the instruments, making them rust and thus affecting their service life.

Scissors, chisels and other tools that require sharpness will have their cutting edges become dull after repeated use, cleaning and disinfection, and will not be used properly in the future.

The shiny metallic appearance of the instruments can easily cause medical staff to be dazzled during long surgical procedures, leading to mistakes.

Product application - Medical devices

Medical Accessories (7)

Before coating

Medical Accessories (8)

After coating: DLC

Medical Accessories (9)

After coating: Hard Cr

The advantages of coatings such as DLC and hard Cr in medical devices

  Main advantages
Production 1. DLC and hard Cr are highly hard and wear-resistant, preventing scratches on the surface of the instruments during the cleaning process and further inducing corrosion.
2. The film layer is uniform and smooth, which does not affect the opening and closing of the scissors and maintains the sharpness of the cutting edge.
3. The coating can be removed without damaging the substrate, and medical devices can be reused.
Productivity 1. The reuse of equipment can effectively reduce production costs.
2. Both the black shiny DLC coating and the white hard Cr coating can effectively prevent medical staff from being dazzled.
Terminal products 1. Significantly increase the lifespan of various medical products and other terminal products. 
2. Reduce the frequency of return repairs for terminal products.

DLC coating parameters

Name Coating
Coating DLC HardCr
Coating composition C Cr
Coating color Black Silvery white
Coating film thickness (μ m) 2-4 2-4
Coating hardness >2500HV >600HV
Coefficient of friction < 0.1 <0.2
Coating temperature (℃) <160 <500
Maximum operating temperature (℃) 300 800